Circuit Diagram

This provides a visual reference for wiring of the components. They aren't true to scale, just meant to be used as reference. Generic micro switches follow a standard pin out with visible markings on the body of the switch. Here's each label markings:

  • (C1) – "common ground".
  • (NO2) – "normally open".
  • (NC3) – "normally closed".

Wired Connections

Just two wired connections are needed for this circuit, which makes it very easy!

  • (C 1) Common from micro switch to Ground on Trinket M0
  • NO 2) Normally open from micro switch to #0 on on Trinket M0

This guide was first published on Mar 21, 2018. It was last updated on Mar 21, 2018.

This page (Circuit Diagram) was last updated on Jun 13, 2021.